Related schema specification: MeasuredQuantity
metadata sheet
https://openminds.om-i.org/instances/measuredQuantity/chlorideReversalPotential
https://openminds.om-i.org/types/MeasuredQuantity
The reversal potential for chloride ions.
chloride reversal potential
BACK TO TOP
https://openminds.om-i.org/instances/measuredQuantity/compensationCurrent
Current injected into a cell to maintain the membrane potential at a target value.
compensation current
https://openminds.om-i.org/instances/measuredQuantity/holdingPotential
Measured membrane potential during a voltage-clamp protocol.
holding potential
https://openminds.om-i.org/instances/measuredQuantity/inputResistance
Total resistance observed by the amplifier during an electrophysiological recording.
input resistance
https://openminds.om-i.org/instances/measuredQuantity/liquidJunctionPotential
A potential difference that develops when two solutions of electrolytes of different concentrations are in contact with each other.
liquid junction potential
https://openminds.om-i.org/instances/measuredQuantity/membranePotential
A quality inhering in a cell’s plasma membrane by virtue of the electric potential difference across it.
http://uri.interlex.org/base/ilx_0106774
membrane potential
https://openminds.om-i.org/instances/measuredQuantity/sealResistance
Resistance of the seal between the pipette tip and cell membrane in patch-clamp recording.
seal resistance
https://openminds.om-i.org/instances/measuredQuantity/seriesResistance
Resistance of the electrode during an electrophysiological recording.
series resistance