ElectrodeArrayUsage

Semantic name:

https://openminds.ebrains.eu/ephys/ElectrodeArrayUsage

Display as:

Electrode array usage



Properties

Required:

device

Optional:

anatomicalLocationOfArray, anatomicalLocationOfElectrodes, contactResistances, lookupLabel, metadataLocation, spatialLocationOfElectrodes, usedElectrode, usedSpecimen


anatomicalLocationOfArray

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/anatomicalLocationOfArray

value type:
instructions:

Add all anatomical entities that semantically best describe the overall anatomical location of the electrode array.

BACK TO TOP


anatomicalLocationOfElectrodes

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/anatomicalLocationOfElectrodes

value type:
instructions:

Add all anatomical entities that semantically best describe the anatomical location of each electrode contact of this array during its use, in the same order that the electrode identifiers for this electrode array have been specified.

BACK TO TOP


contactResistances

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/contactResistances

value type:
embedded object array (2-N) of type
instructions:

Enter the contact resistance for each electrode of this array during its use, in the same order that the electrode identifiers for this electrode array have been specified.

BACK TO TOP


device

Piece of equipment or mechanism (hardware) designed to serve a special purpose or perform a special function.

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/device

value type:
linked object of type
instructions:

Add the electrode array used.

BACK TO TOP


lookupLabel

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/lookupLabel

value type:
string
formatting: text/plain; singleline
instructions:

Enter a lookup label for this device usage that may help you to find this instance more easily.

BACK TO TOP


metadataLocation

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/metadataLocation

value type:
linked object array (1-N) of type
instructions:

Add all files or file bundles containing additional information about the usage of this device.

BACK TO TOP


spatialLocationOfElectrodes

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/spatialLocationOfElectrodes

value type:
embedded object array (2-N) of type
instructions:

Add all coordinate points that best describe the spatial location of each electrode contact of this array during its use, in the same order that the electrode identifiers for this electrode array have been specified.

BACK TO TOP


usedElectrode

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/usedElectrode

value type:
string array (1-N)
formatting: text/plain; singleline
instructions:

Enter the identifiers of all electrodes that are actually in use for this array.

BACK TO TOP


usedSpecimen

schema_specifications

semantic name:

https://openminds.ebrains.eu/vocab/usedSpecimen

value type:
linked object of type
instructions:

Add the state of the tissue sample or subject that this device was used on.

BACK TO TOP